Maintenance Agreements

Preventative Maintenance

E & J Geothermal, Inc.starstarstarstarstar4.8 / 5

251 Total Reviews /files//ej_geo-logo.png319-519-0261$400 East Main Street, SOLON IA

E&J Geothermal knows how much of an investment a new heating, air conditioning, air quality or geothermal system can be. That's why we want to help you protect your investment!

Preventative Maintenance Benefits

  • E&J Geothermal sells custom filters that are reusable, this saves money and is environmentally economical
  • Priority service scheduling
  • Extends life of equipment
  • Peace of mind
  • Minimizes chance of breakdowns
  • Maximize unit efficiencies
  • Meets manufacturers’ service requirement for warranty coverage
  • May qualify for utility rebates
Bosch Geothermal Heat Pumps
Geothermal
York Furnaces
Furnace
Bosch Geothermal Heat Pumps
Air Conditioner
Bosch Geothermal Heat Pumps
Gas Fireplace
Bosch Geothermal Heat Pumps
Generator
Inspect air coil & fan housing Remove and clean burners Clean condenser coil Remove and clean glass Verify proper gas pressures
Check loop water, heat exchanger, and hot water generator Remove, test, and clean flame sensor Check electrical components Check blower for proper operation Change oil (Oil not included)
Check condensate drain and pipe drain Brush heat exchanger and check for cracks/holes Check and record amp draw on compressor Vacuum out fireplace and logs Change air filter (Filter not included)
Add condensate drain pain treatment Measure CO reading in flue and plenum Check and record amp draw on blower motor Re-spray inside of enclosure with flat black paint Change oil filter (Filter not included)
Check back-up heat Clean and flush condensate drain Clean condensate trap and pump (if applicable) Replace logs and redress embers Verify proper operation of transfer switch
Check control panels Inspect evaporator coil Visual leak inspection on evaporator coil and condenser coil Check for proper venting operations Record all reading and hour usage
Check contactors, capacitors and relays Test amp draw on blower motor Verify refrigeration charges (Refrigerant not included) Check electrical components for proper operations Check electrical components for proper operations
Check compressor electrical draws Inspect electrical components Add condensate drain pan treatment
Check and clean filter Replace air filters (Filters not included)
Yearly Yearly Yearly Every 2 Years Yearly
Bosch Geothermal Heat Pumps
Geothermal
York Furnaces
Furnace
Bosch Geothermal Heat Pumps
Air Conditioner
Inspect air coil & fan housing Remove and clean burners Clean condenser coil
Check loop water, heat exchanger, and hot water generator Remove, test, and clean flame sensor Check electrical components
Check condensate drain and pipe drain Brush heat exchanger and check for cracks/holes Check and record amp draw on compressor
Add condensate drain pain treatment Measure CO reading in flue and plenum Check and record amp draw on blower motor
Check back-up heat Clean and flush condensate drain Clean condensate trap and pump (if applicable)
Check control panels Inspect evaporator coil Visual leak inspection on evaporator coil and condenser coil
Check contactors, capacitors and relays Test amp draw on blower motor Verify refrigeration charges (Refrigerant not included)
Check compressor electrical draws Inspect electrical components Add condensate drain pan treatment
Check and clean filter Replace air filters (Filters not included)
Yearly Yearly Yearly
Bosch Geothermal Heat Pumps
Gas Fireplace
Bosch Geothermal Heat Pumps
Generator
Remove and clean glass Verify proper gas pressures
Check blower for proper operation Change oil (Oil not included)
Vacuum out fireplace and logs Change air filter (Filter not included)
Re-spray inside of enclosure with flat black paint Change oil filter (Filter not included)
Replace logs and redress embers Verify proper operation of transfer switch
Check for proper venting operations Record all reading and hour usage
Check electrical components for proper operations Check electrical components for proper operations
Every 2 Years Yearly